Solubility System: 1-Chlorobutane with Water (Original Report)

Variables:
Temperature: 298 K
Prepared By:
Ari L. Horvath
Experimental Data:
Table 1
T (°C)c1 (mol/dm3)w1 x1
259.43 x 10-38.7217000
Method/Apparatus/Procedure:

The modified generator column method was used. A chromatographic column was coated with liquid 1-chlorobutane. An aqueous phase was generated by pumping water through the coated generator column. The aqueous solution was analyzed by a gas chromatographic method using a gas chromatograph equipped with a flame ionization detector.

Source and Purity of Materials:

(1) Source not given. At least 99% pure by GC analysis.
(2) Baker-analyzed HPLC grade.

Estimated Errors

Temperature: ±0.1 K.
Solubility: ±1.0%.

References:

No references.